Supported manufacturers:

Solar-Log™ devices work with inverters made by:

  1. SMA
  2. KACO
  3. DIEHL
  4. POWER-ONE
  5. MASTERVOLT
  6. AROS
  7. SOLARMAX
  8. DELTA
  9. REFU
  10. FRONIUS

… and many more:

Please select a model:

Overview of all manufacturers

An overview of the equipment components and scope of services for the Solar-Log500.



Inverter communication  
Bluetooth (BT) +
WiFi (wireless LAN) +
Bluetooth/WiFi +
Powermanagement (PM+) +
Powermanagement (PM+) / GPRS -
Powermanagement (PM+) / WiFi +
GPRS -
Central Inverter SCB and SMB -
Max. number of inverters up to 10
Communication interface 1 x RS485/RS422
Inverter mixed operation several inverters per manufacturer
Recommended max. plant size 50 kWp
Max. cable length Max. 1000m1)
Plant monitoring  
String monitoring (depending on type of inverter) +
Inverter failure +
Status of power monitoring +
Status of fault +
Connection of sensors (temp./wind) +
Connection to Sensor Basic +
E-mail and SMS alarm +
Local alarm (pot.-free contact) -
Yield forecast +
Degradation calculation +
Self-produced energy consumption: Digital electricity meter +
Self-produced energy consumption: Control of ext. consumers -
Visualisation  
Integrated web servers +
Graphic visualisation - PC local +
Graphic visualisation - USB flash drive -
Graphic visualisation - internet +
LED - status display +
Display on device 2-line text display
Operation on device Keypad entry
Large display RS485/S0 pulse +
Interfaces  
S₀ in/out + / +
Réseau Ethernet +
Lecteur flash USB -
Modem, analogique / GPRS(GSM) / DSL -
Contact sans potentiel (relais) -
Contact d'alarme (antivol) -
General data  
Network voltage / device voltage 115 V - 230 V / 12 V
Current consumption 3W
Ambient temperature -10°C to +50°C
Housing/dimensions (W x D x H) in cm Plastic / 22,5 x 4 x 28,5
Assembly Wall-mounted
Protection level IP 20 (only for interior use)
Connection to Solar-LogTM WEB +
Multi-lingual (DE, EN, ES, FR, IT, NL, DA) +
Memory, micro SD, 2 GB, Endless-loop data recording +
Warranty over age 5 years


1) Depends on inverter used and cable length. (Specifications may differ depending on device model)